Neocare Infant Ventilator :
Medisys Neocare

The MEDISYS NEOCARE is a continuous flow generating ventilator intended for use on neonate, infant and pediatric patients. It is microcontroller based. All set and monitored parameters are displayed on a LCD Screen, The Oxygen blender is servo controlled with closed-loop feed-back-system.

The ventilator provides for modes like CMV, ASSIST, SIMV and SPONTANEOUS with CPAP facility The monitoring of data include Expired Tidal Volume, Minute Volume,  Peak Inspiratory Pressure, Frequency, I/E Ratio and FiO2. The sensitivity is Flow Triggered and negates any false triggering due to leakage in the breathing circuit.

The Ventilator is capable of sensing a flow as low
as 10 ml/second drawn by the patient. This high sensitivity resolution is of vital importance for neonate and pediatric ventilation, The monitoring is done in close proximity to the patient to achieve accurate measurement.
The safety features include composite alarms, adjustable safety release in case of high pressure.



  
   
  Technical Specifications
Recommended Application
:
Neonatal, infant and pediatric patients
Flow
:
2-25 Litre Per Minute
Tidal Volume
:
6 to 300 ml
Modes of Operation
:
AC, SIMV/IMV, CPAP with backup Ventilation and Standby
Inspiratory Time
:
0.2 to 3.O seconds
I:E ratio
:
1:1 to 1:10 (Ac)
:
I: 1 to 1 : 60 (SIMV)
 
:
Inverse 1: 1 to 4: 1
Frequency
:
1 to 150 breaths per minute
Triggering
:
Flow Triggering (1-10 1pm)
Expiratory Pressure
:
0 to 20 cmH2O
Inspiratory Pressure Limit
:
5 to 50 cm H2O
Manual Breath
:
Electronically Controlled with set
:
Inspiratory Time and Pressure
Alarms
:
High/Low Inspiratory Pressure
 
:
Loss of inlet gas
 
:
Apnea
:
Electrical Power Failure
Alarm Mute
:
30 Seconds
Safety Pressure Relief
:
15 to 50 cm H2O
Display
:
5.7 inches graphical LCD
Indicators
:
Set Parameters :
:
Frequency, Apnea Rate, Insp. Time,
:
Sensitivity, and FiO2
:
Measured Parameters :
:
Frequency, Peak Insp. Pressure, MAP,
:
Expired Tidal Volume,
:
Spontaneous Expired Volume,
:
Minute Volume,
:
FiO2
 
:
Calculated Parameter : I:E Ratio
Ventilation Curves
:
Pressure-Time and Flow-Time
Dimensions (Ventilator Module)
:
28cm(W) x 32cm(D) x 32cm(H)
Weight
:
8.2 kgs
Power Requirements
:
220 to 240 VAC, 50 Hz
Accessories
:
Standard :
:
Proximal Flow Sensor, Breathing Circuit,
:
Heated Humidifier, Oxygen Sensor,
:
Mobile Stand
Optional
:
Air Compressor with Mobile Stand
     