Defibrillator

 
   
   
   
 
 
Medivent Electro :
MICRO PROCESSOR CONTROLLED CRITICAL CARE VENTILATOR
MEDISYS Medivent Electro is a simple to operate Micro-processor based intensive care ventilator with in-built air supply, The modes of ventilation available are CMV, AV + CMV, SIMV, spontaneous, BiPAP and APRV , It also provides for PSV, PCV, PEEP/CPAP, Extended lnspiratory Phase (EIP) and Apnea Back-up ventilation, Pressure Control Ventilation may be applied to each mechanical breath, High airway pressure can be limited by adjusting the Peak lnspiratory Pressure (PIP) control, During apnea, the ventilation automatically switches to CMV , But as soon as the patient starts breathing spontaneously the ventilation returns to the earlier mode The Tidal Volume, Frequency, lnspiratory Time, EIP, I:E ratio and Total Frequency ere displayed
digitally. The Airway pressure is displayed as Bar Graph, The FiO2 can be adjusted from 21 to100% The Alarm system is activated in the event of O2 supply failure, low lnspiratory pressure, limiting PIP and low system pressure (LSP) or disconnection in the patient's airways.
 
  Specifications
Functional Characteristic
Gas supply
Volume preset Constant Flow Generator
O2 at 3 to 4 bar and air from internal compressor. For 21 % FiO2, Oxygen supply is not needed
Modes
CMV, AV+ CMV, SIMV SPONT, BIPAP and APRV
Oxygen concentration
21 to 100%
Frequency
6 to 40 bpm (CMV), 1 to 40 bpm (SIMV)
Tidal Volume
80 cc to 1200 cc
lnspiratory time
0.4 sec to 3 secs,
EIP
0 to 2 secs
Demand flow
Maximum 120 Liters/min
CPAP
0 to 15 cm H2O (all modes)
Trigger sensitivity
1 to 8 cm H2O below CPAP
Pressure support ventilation
Adjustable in steps from 3 to 24 cm H2O.
BiPAP
EPAP from 0 to 10 cmH2O & IPAP from 3 to 24 cm H2O. Changeover @ 6 to 40 per minute
Peak inspiratory pressure
Adjustable in steps from 10 to 60 cmH2O.
APRV
intermittent release of pressure from set pressure ranging from 3 to 24 Cm H2O at @ 6 to 16/min
Oxygen failure alarm
Activates in case O2, supply is discontinued
Apnea backup ventilation
Automatic switch-over to pre-selected CMV once the apnea conditions detected.
Humidification
Heated
Electrical requirement
200 - 220 V AC, 50 HZ 700 VA
   

Warranty
TWELVE MONTHS against any manufacturing defect.
A totally Indigenous product with prompt After- Sales-Service

The Company reserves the right to change/ modify the
specifications without any notice

     