Products
 
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
 

Defibrillator

 
   
   
   
 
 
Excelsior : ANAESTHESIA WORKSTATION WITH VENTILATOR
All controls are within your arm's reach

MEDISYS EXCELSIOR is a High End Anaesthesia Workstation that has an in-built Electrically Operated Micro-Controller Based Ventilator.

Special care has been taken to keep it very simple, sturdy, compact and user friendly.

ANAESTHESIA VENTILATOR
• Micro-Controller Based Electrically Driven
• Bright Display of Parameters
• Display of Airway Pressure in Bar graph
• Compatible with Circle Absorber or Bain's Circuit
• Automatic Spill Device
• Adjustable Safety Valve
• lnspiratory Hold for better distribution of gas
• Variable 1: E Ratio

Just Select The Controls & Relax
5 Column Flow meter
Pneumatic Suction
Patient Block
Ventilator
  Specification
Classification
:
Flow Generator Type
Driving Source
:
220vAC
Mode
:
CMV
Tidal Volume
:
50 to 1200 ml
Frequency
:
6 to 40 bpm
Insp. Time
:
0.4 to 3 Seconds
Insp. Hold
:
0 to 2 Seconds
I I E Ratio
:
1:1 to 1:5
Alarms
:
Patient Disconnection High Insp. Pressure. Low Insp. Pressure
Safety Valve
:
Adjustable : 10 to 60 Cm H2O
Power
:
60W
 
  Structure
  • Made of Aluminium Extruded Tubes and Channels with Powder Coated Finish
  • 2 Drawers with Smooth Sliding Channels
  • Sliding Writing Table
  • Antistatic Large Castor Wheels, Front Wheels with Brakes
  • Dip Stand with Double Hook
  • Handle on each side for Easy Maneuverability
  • Equipped with Electrical Distribution Box
  • Space for mounting 2 Vaporizers

VAPORIZER MANIFOLD
Provision for mounting 2 Temperature and Flow Compensated Vaporizers.

FLOWMETER MANIFOLD

5 Tube Flowmeter Set
• 2 Each High & Low Range Tube Set for O2 & N2O
• 1 High Range Tube for AIR
• Each Gas Control Valve fitted with Colour and Shape Specific Control knobs
• Fitted with Oxygen Ratio Controller which ensures minimum 25% O2    Concentration, If Oxygen delivery is altered, ORC automatically readjusts    proportionate delivery of N2O, thereby maintaining pre-set Oxygen    Concentration

Gas
Flowmeter
Range
O2
Double
0 to 1 Litre/min
1 to 12 Litre min
N2O
Double
0 to 1 Liter/min
1 to 12 Litre/min
AIR
Single
100 to15000 cc/min
GAS INLET :
a) Cylinder Inlet : 4 Forged Brass Pin Indexed Yokes, 2 each for O2, & N2O with Colour Coded Cylinder Pressure Gauges at eye level.

b) Pipeline Inlet : Non-interchangeable Pipeline Inlet for O2, N2O & AIR with separate Pipeline Pressure Gauges on the front at eye level,

Application
Gas
Qty.
Pressure Gauge Range
Cylinder
O2
2
0-250 kg/cm2
Cylinder
N2O
2
0-250 kg / cm2
Pipe Line
O2
1
0-7 kg/cm2
Pipe Line
N2O
1
0-7kg/cm2
Pipe Line
AIR
1
0-7kg/cm2
Vacuum System
VACUUM
1
0-760mm/Hg.
 
PRESSURE REGULATORS
4 First Stage Regulators, 2 each for O2 & N2O, 2 Second Stage Regulators for maintaining System Pressure, 1 each for O2 & N2O.

AIR/N2O INTERLOCK
This Interlock system eliminates the possibility of selecting AIR with N2O. Oxygen is allowed to flow with N2O or AIR.

NITROLOCK WITH ALARM
Oxygen Failure Alarm is activated when O2 delivery falls below 1 Lpm. It also locks the flow of N2O. Alarm will be on till the fault is rectified.

ALARM 'ON-OFF' Switch
It is provided to keep the Audible Alarm off.

NON RETURN VALVE WITH SAFETY RELEASE
Protects Reverse Flow from Patient Circuit towards Vaporizers, Also acts as a Safety feature to blow-off excess pressure built-up in the Patient Circuit.

OXYGEN FLUSH
Monostable Type Guarded Push Button fitted for supply of fresh Oxygen to the Patient Circuit.

VACUUM SYSTEM
Consists of Vacuum 'ON-OFF' Switch, Vacuum Control Valve with Pressure Gauge &Vacuum Collection Bottle, The System operates on AIR.

FiO2 MONITOR
FiO2 Monitor is provided to continuously record the delivered O2, Concentration.

CIRCLE ABSORBER
1. Ideally suited for Low Flow Anaesthesia System.

2. 'O' Ring fitted taper joints ensure 100% leak proof system and easy maneuverability.

3. Cannisters can be taken out for refilling and push-fitted again to the circuit set-up very easily.

4. Supplied with 2 Cannisters, APL Valve & Patient Circuit.

5, Visual Unidirectional flow indicator at lnspiratory & Expiratory Valve.

6. Supplied with BAG-VENT Switch for easy changeover between Manual & Automatic modes.

 
Shelf
Height Cm.
Depth Cm.
Width Cm.
Maximum Load (Kg.)
Top
149
35
65
22
Table
92
31
53
11

Warranty

TWELVE MONTHS against any manufacturing defect.
A totally Indigenous product with prompt After- Sales-Service

The Company reserves the right to change/modify the
specifications without any notice
     
  www.medisysindia.net  
  Home : About Us : Products : Contact Us : Send Enquiry Mail
Copyright 2007 © Medisys